Technical characteristics
horizontal solar tank
Coating of the inner tank: Glasslined coating
Internal tank corrosion protection:
- Glasslined coating completely safe and keeping the hard
water clean and hygienic - Magnesium anode 3 cm in diameter and 50 cm long.
Welding: Plasma welded (CO2)
Insulation: High density expanded polyurethane (48Kgs/m )
Inner Vessel Maximum Working / Test Pressure: 5 bar – 6 bar (10 min)
Maximum service temperature: 75°C
Siding : GI With Powder Coating, Resistance to
chemical attack and corrosion in a humid environment
Dimensions and capacities
horizontal solar tank


[table id=2 /]
Technical characteristics of the collector

[table id=3 /]
WATER STORAGE TANK SPECIFICATIONS
STEEL- ENAMEL
1. Storage tank: Made of 3 mm thick enamel coated steel with glass lined / porcelain enamel coating technology,
baked at 850°C temperature. Enameling is carried out in our state-of-the-art in-house production facility. Each tank is
QC checked before its release, thus ensuring a superior quality of enamel.
2. Thermal insulation: Eco-friendly high-density polyurethane foam (PUF) that minimizes heat loss while
maintaining hot water temperature
3. Siding: Aluminum with powder coating.
4. Wide rubber protected round flange: Clever and innovative design, to easily remove lime scale and directly
access the electrical components.
5. Foot seal: Of EPDM, in non-toxic silicone material, which prevents contact between water and the ange which it
protects against electrolysis and corrosion, specially manufactured, in accordance with generally accepted
specications for heat resistance.
6. Electrical resistance: At the rate of charge in accordance with the standards of the country of destination.
(Optional item that allows electric current to be used as a back-up power source). All electrical components are in
accordance with EN 60335-1 and EN 60335-2-21 standards.
7. Automatic regulated thermostat: bipolar protection with auxiliary fuse. All electrical components are in
accordance with EN 60335-1 and EN 60335-2-21 standards.
8. Protective cover: Designed to ensure the correct ventilation and sealing of the electrical part against bad
weather.
9. Cold water inlet: Male thread tube with 3/4” BSP brass end for even water stratication, and 7 bar safety valve
for pressure relief.
10. Hot water outlet: 3/4” BSP tube male threaded end
11. Hot water inlet from panel: 3/4” BSP tube male threaded end.
12. Connection position of the 3 bar safety valve: 3/4” BSP tube male threaded end.
220 LPD Tank connection Diagram
- Propelene glycol water upto 25 Ltrs for 220 LPD
- Pump Air lock to be removed after lling Glycol. The pump to release
air when we put glycol only for the rst time It can be opened with a coin as well - Every product has a sticker on its back with clear diagram on connection
- Cover for pump and controller units with metal housing.
- PRV (Pressure Release valve or Safety valve) to be connect the cold water inlet port
- Air vent pipe to be additionally attached about 8 inches in height
- Pump work is to pump hot water mixed with glycol to tank, Pump operates through
temperature sensor valve
300 LPD Tank connection Diagram
- Propelene glycol water upto 30 Ltrs for 300 LPD
- Pump Air lock to be removed after lling Glycol. The pump to release
air when we put glycol only for the rst time It can be opened with a coin as well - Every product has a sticker on its back with clear diagram on connection
- Cover for pump and controller units with metal housing.
- PRV (Pressure Release valve or Safety valve) to be connect the cold water inlet port.
- Air vent pipe to be additionally attached about 8 inches in height
- Pump work is to pump hot water mixed with glycol to tank, Pump operates through
temperature sensor valve